Item | Specification |
---|---|
Weathering
|
Weathering course on the open terrace with laying tile on it (reduction of heat) |
Steel
|
FE – 500 Grade |
Wires
|
Havells |
Bedroom
|
AC, TV, and telephone pointsLoft |
Living / Dining
|
WashbasinTV and Telephone points |
Terrace
|
3’6″ high parapet wall in 4.5 “ thick brickwork in the terrace A small area with Roof cover near the staircase if rain occurs |
Lift
|
6 passengers lift (Sri space lifts)Clearance Certificate from Lift authority for Lift |
Compound
|
5’ high compound wall with 4.5” brickwork around the building with gate pillars MS grill gates with exterior quality paint |
Doors
|
Main Door First Class Teak Frame and Solid teak wood door 7′ x 3’3″ with 6 lever Godrej lock |
Lobby and Staircase Flooring
|
Granite flooring Hand rail stainless steel |
Flooring
|
Joint rarified Ties Living, Bedroom, Balcony & Kitchen. |
Bathroom
|
Anti-skid Ceramic Tile floor with waterproof coating Provision for exhaust fan with wire mesh “American standard” bathroom fittings Geyser connection for bathroom One Tipton and shower hose per toilet Concealed plumbing arrangements |
Common Area Lighting
|
Adequate light points shall be provided around the building. Sufficient exterior lighting all around the premises |
Soil test and Pest Control
|
Pre-Construction Anti-termite treatment as per IS 6313 -1981 Pest control measures up to plinth level with a guarantee letter from the concerned authorities Soil testing to be done |
Cement
|
Good Quality 53 grade- OPC Cement |
Painting
|
4 gauge or 6 gauge pipes Prince ISI (6 for ground and 4 for walls) |
Sand
|
Good Quality Sand |
Kitchen
|
Stainless Steel sinkGranite top platform 4′ Ceramic tile above the countertop Taps for Corporation Water and Bore Water Provision for electric chimney Loft Concealed plumbing arrangements |
Bathroom fittings
|
American Standard |
Security system
|
Video Door Phone & CCTV |
Borewell
|
Borewell provided and connected to overhead tank electric Motor 1.5 HP |
Underground
|
15000 liters sump of R.C. ConstructionElectric motor 1 HP |
Overhead Tank
|
Overhead tank of required capacity for Metro water and Borewell Submersible Electrical motors of 1 HP and 1.5 HP capacity for sump and borewell respectively Water level Indicators |
Electrical switches
|
Legard/ Anchor rome/ Havells |
Foundation
|
Earthquake Resistance RCC Framed Structure with RCC Column Connected by RCC Plain Beam. |
Landscaping
|
Landscaping did around the building |
Electrical Points
|
Living / Dining 1 Bell point 1 Light point for Main Door 2 Fan Points 1 point for Night Light 3 Nos of 5Amps Plug Point 1 No of 15 Amps Power plug for TV and Phone point 1 Phone socket Bedroom 2 way control for Light and Fan Point 1 No 5 Amps point and 1 No 15 Amps point Power plug for AC 1 Phone socket Kitchen 2 Lights and 1 Fan 2 Nos of 5 Amps and 2 Nos of 15 Power plug for AC 1 Exhaust fan point Toilets 2 Lights 1 5 Amps and 1 15 Amps point 1 Exhaust point Balcony 2 Lights Utility 1 Lights 1 No of 15 Amps point for washing machine Terrace 1 Lights |
Shutters
|
Living Area BalconyFrench Door |
Windows
|
UPVC WindowsSquare Rod Grills |
Ventilators
|
3′ x 2′ UPVC FrameGlazed Louvers Provision for exhaust fan Square Rod Grills |
Foundation and Superstructure
|
RCC framed structure RCC columns, beams, slabs, brick, masonry, pillar walls Basement height for 3feet Floor height 9’6” clear |
Note:Specifications can be changed as per manufacture’s availability.
Click on the Floor plan to Download the PDF Download
S.NO | FLOOR | SQFT | BHK | AVAILABLE |
---|---|---|---|---|
1 | III | 1395 | 3 | |
2 | III | 1115 | 3 | |
3 | III | 1115 | 2 | |
4 | III | 1700 | 3 | |
5 | II | 1390 | 3 | |
6 | II | 1155 | 3 | |
7 | II | 1115 | 2 | |
8 | II | 1700 | 3 | |
9 | I | 1390 | 3 | |
10 | I | 1155 | 3 | |
11 | I | 1115 | 2 | |
12 | I | 1700 | 3 |
Block No.24, Plot No.9 &.11, Door No. 6, 29th Street, Nanganallur, Chennai 600 061. ( Sivan kovil opposite Road)
Nanganallur
Chennai
India
Tamil Nadu
600061